LIDA® Discrete Mesh Anodes — a precious metal oxide on expanded titanium mesh designed to protect steel reinforced concrete structures. LIDA® anodes come in two configurations and are available in various lengths from 100 mm to 400 mm that can be combined to meet specific needs.
Dimensions:
| |
Stargard 19 |
Stargard 25 |
| Diameter |
19 mm (.75 in) |
25.4 mm (1 in) |
| Installation Hole Diameter |
25.4 mm (1 in) |
31.75 mm (11/4 in) |
| Lengths |
Variable – See Anode Performance |
Variable – See Anode Performance |
Anode Performance:
| Maximum Current Density (CD) @ Anode |
216 mA/m2 (20 mA/ft2) |
|
|
|
|
|
| Mesh Length, ”L”, mm (ft) |
100 (.325) |
150 (.492) |
200 (.658) |
250 (.817) |
300 (.983) |
350 (1.125) |
400 (1.31) |
| Anode Surface Area, m2 (ft2) |
.020 (.215) |
.030 (.325) |
.040 (.430) |
.050 (.545) |
.061 (.660) |
.071 (.770) |
|
| Stargard 19 Current Rating @ Max CD, mA |
4.4 |
6.6 |
8.8 |
11.0 |
13.1 |
15.3 |
|
| Stargard 25 Current Rating @ Max CD, mA |
6.6 |
|
13.2 |
|
|
|
26.3 |
| Expected Life |
50 years |
|
|
|
|
|
|
| Anode Coating |
Iridium Oxide |
Mixed Metal Oxide |
|
|
|
|
|
Click here for a print friendly PDF version.

LIDA® is a U.S. registered trademark of ELTECH Systems Corporation.
LIDA® is a registered
trademark worldwide of Oronzio de Nora SA licensed
exclusively to the De Nora Elettrodi Network.
LIDA TSA™ a trademark of ELTECH Systems Corporation and De Nora
Elettrodi Network.
All information, recommendations and suggestions appearing
herein concerning the
use of our products are based upon tests and data
believed to be reliable. However, it is
the user’s responsibility
to determine the suitability for his own use of the products
described
herein. Since the actual use by others is beyond our control, no guarantee,
expressed or implied, is made by De Nora Elettrodi Network Companies as
to the effects
of such use or the results to be obtained, nor does De
Nora Elettrodi Network Companies
assume any liability arising out of the
use by others of the products referred to herein. In
addition, the information
herein is not to be construed as absolutely complete since additional
information may be necessary or desirable when particular circumstances
exist or because
of applicable laws or government regulations. Nothing
herein contained is to be construed
as a recommendation to infringe any
patent.
|
 |